top of page
Enphase QD-12-20-120-CUT-01 QD Cable, Small Landscape 4x12AWG for 60-72 Cell

Enphase QD-12-20-120-CUT-01 QD Cable, Small Landscape 4x12AWG for 60-72 Cell

SKU: QD-12-20-120-CUT-01
$38.50Price

INDIVIDUAL CUTS MUST BE MULTIPLES OF 3. WARNING: Cut cable lengths may include 2 sections of cable with a minimum of 12 micro connectors on the shorter cable length. Use of field wireable connectors and/or junction box may be required to follow design guidelines. · QD cable (Small Landscape) (4x12AWG) for 60-72 cell. · Connector spacing is 2.4m (7.9ft). · 2.0m (6.6ft) max spacing between microinverters. · 4-pin male connectors plug directly into the IQ8 Commercial Microinverters. Connector count varies based in cut length and must be multiples of 3. · Center tap every 6 connectors, first center tap will be after 3 or 6 connectors and cut will start at connector 1 or 4

 

QD Cable (landscape, 2.4 m)

Supporting faster, simpler, and more reliable installations, the QD Cable is a continuous length 12 AWG cable with pre-installed connectors for IQ Commercial Microinverters. The cable is handled like standard outdoor-rated electrical wire, allowing it to be cut, spliced, and extended as needed.

The QD Cable works with IQ8 Commercial Microinverters and provides self-phase balancing and neutral sensing for phase loss protection.

This SKU of QD Cable is used with landscape PV modules, and comes with 2.4 m (7.9 ft) connector spacing.

  • Neutral sensing for phase loss protection
  • Locking-type connectors
  • Rated for outdoor, wet environments, sunlight resistance, and oil resistance
  • Self-phase balancing
  • Lightweight and simple for fast installation
  • Modularly expandable
  • Reduction in balance-of-system costs and installation time
  • Phase ID marked on QD Cable connectors for easy identification (C1: L1-L2, C2: L2-L3, and C3: L3-L1 sequentially)
  • Separate center-feeding connectors for each AC branch circuit for maintaining <1% voltage rise
  • QD Cable and Accessories data sheet | Download

Technical Specifications

  • QD Cable: 4 conductors, 12 AWG
  • Outer diameter: 11.5 mm
  • Voltage rating: 600 V (connector rating up to 277 VAC)
  • Certification: UL 3003 (raw cable), UL 9703 (cable assemblies), and DG cable
  • Max. AC conductor resistance (20C): 5.43 ?/km 12 AWG
  • Flame test rating: FT4
  • Compliance: RoHS, OIL RES I, CE, UV resistant, and combined UL for the United States
  • Conductor type: THHN/THWN-2 dry/we
  • Connector spacing: 2.4 m (7.9 ft)

Compatibility

  • IQ8 Commercial Microinverters
bottom of page